Standard

JEDEC JESD24-3

Publisert

Merknad: Denne standarden har en ny utgave: JEDEC JESD24-3

For bestilling og priser av dette produktet ta kontakt med salg@standard.no

Omfang

The purpose of this test method is to measure the thermal impedance of the MOSFET under the specified conditions of applied voltage, current and pulse duration. The temperature sensitivity if the forward voltage drop of the source-drain is used as the junction temperature indicator. This method is particularly suitable to enhancement mode, power MOSFETs having relatively long thermal response times. This test method may be used to measure the thermal response of junction to a heating pulse, to ensure proper die mountdown to its case, or the dc thermal resistance, by the proper choice of the pulse duration and magnitude if the heating pulse. 

Dokumentinformasjon

  • Standard fra JEDEC_AC
  • Publisert:
  • Versjon: 0
  • Varetype: IS
  • Tilleggsinformasjon
  • Addendum to JEDEC JESD 24