Standard

IEC 60034-12:2016 ED3

Revidert

Merknad: Denne standarden har en ny utgave: IEC 60034-12:2024 ED4

Rettelser og tillegg kjøpes separat.

Språk
Tjenester

Omfang

IEC 60034-12:2016 specifies the parameters for eight designs of starting performance of single-speed three-phase 50 Hz or 60 Hz cage induction motors in accordance with IEC 60034-1 that: - have a rated voltage up to 1 000 V; - are intended for direct-on-line or star-delta starting; - are rated on the basis of duty type S1; - are constructed to any degree of protection and explosion protection. The main changes with respect to the previous edition are as follows: - new design letter E for extended efficiency motors, explanation of all design letters, and description of new designs NE, NEY, HE, and HEY; - addition of a reference to IEC 60079-7; - addition of a formula to calculate locked rotor current from apparent power.

Dokumentinformasjon

  • Standard fra IEC
  • Publisert:
  • Tilbaketrukket:
  • Utgave: 3
  • Versjon: 1
  • Varetype: IS
  • Products.Specs.pages
  • ICS 29.160.01
  • ISO TC TC 2

Produktrelasjon

Produkt livssyklus