Standard

SN-EN 1996-1-2:2024 (Prestandard)

Published

Corrigendums and amendments are bought separately.

Language
Services

This is a Norwegian Prestandard

The Norwegian Prestandard SN-EN 1996-1-2:2024 represents a second-generation Eurocode. Prestandards (SN-EN) for second-generation Eurocodes are published to provide the industry with an opportunity to familiarize itself with the content. These prestandards do not replace the first-generation Eurocodes.

Read more about Norwegian Prestandard 

Follow this link for the valid version of NS-EN 1996-1-2.

In Norway, all second-generation Eurocodes will be published collectively as Norwegian Standards (NS-EN) along with corresponding national annexes. All first-generation Eurocodes with national annexes will remain valid Norwegian standards until then and will be withdrawn simultaneously with the publication of the second-generation Eurocodes.

Abstract

1.1 Scope of prEN 1996-1-2(1) This document gives rules for the design of masonry structures for the accidental situation of fire exposure. This document only identifies differences from, or supplements to, normal temperature design.(2) This document applies to structures, or parts of structures, that are within the scope of EN 1996-1-1 or EN 1996-3 and are designed accordingly.(3) This document gives rules for the design of structures for specified requirements in respect of the aforementioned functions and the levels of performance.(5) This document does not cover masonry built with natural stone units according to EN 771-6.(6) This document deals with:- non-loadbearing internal walls;- non-loadbearing external walls;- loadbearing internal walls with separating or non-separating functions;- loadbearing external walls with separating or non-separating functions.1.2 Assumptions(1) The assumptions of EN 1990 and EN 1996-1-1 apply to this document.(2) This document is intended to be used together with EN 1990, EN 1991-1-2, EN 1996-1-1, EN 1996 2 and EN 1996-3.(3) In addition to the general assumptions of EN 1990 and EN 1996-1-1, the following assumptions apply:- the choice of the relevant design fire scenario is made by appropriate qualified and experienced personnel, or is given by the relevant national regulation;- any fire protection measure taken into account in the design will be adequately maintained.

Document information

  • Standard from SN
  • Published:
  • Edition: 2024-09
  • Version: 1
  • Document type: ENV
  • Pages
  • ICS 13.220.50
  • ICS 91.010.30
  • ICS 91.080.30
  • National Committee SN/K 370/AG 01

Legal references

EU law:
Law referenceRestrictions
305/2011

Product Relations

Product life cycle