Standard

SAE AS8036A

Publisert
For bestilling og priser av dette produktet ta kontakt med salg@standard.no

Omfang

This SAE Aerospace Standard (AS) specifies minimum performance standards for the following types of fire detection instruments intended for use in protecting aircraft cargo compartments, galleys, electronic equipment bays and other similar installations. Types Type I: Carbon monoxide, an instrument which will actuate an alarm signal when the concentration of carbon monoxide in air exceeds a specified value. Type II: Smoke detector, electronic, an instrument operating on the principle of smoke particles modifying the relationship between a light beam and electronic light sensor which will actuate an alarm signal when the concentration of smoke in air exceeds a specified value. Type III: Deleted Type IV: Smoke detector, electronic, an instrument operating on the principle of smoke particles modifying the current in an ionization chamber which will actuate an alarm signal when the concentrations of smoke in air exceeds a specified value. Type V: Same as Type IV except maximum operating altitude is 18 000 feet (5486 m) when installed in a non-pressurized area.

Dokumentinformasjon

  • Standard fra SAE_AC
  • Publisert:
  • Versjon: 0
  • Varetype: IS