NS-EN 4839-003:2018

Published

Corrigenda and amendments are bought separately.

Language
Services

Abstract

This European Standard specifies the required characteristics for three-pole, arc fault circuit breakers, rated currents from 3 A to 25 A, switching capacity 65 In, for use in aircraft electrical systems. Their operating temperatures are between − 40 °C to 85 °C at a maximum altitude of Z = 15 000 m. The thermal protection is temperature compensated and operates between − 55 °C and 125 °C.These arc fault circuit breakers are operated by a push-pull type single pushbutton (actuator), with delayed action "trip-free" tripping.They will continue to function up to the short-circuit current.

Document information

  • Standard from SN
  • Published:
  • Edition: 2018-10
  • Version: 1
  • Document type: NAT
  • ICS 49.060
  • National Committee ASD-STAN

Product Relations

  • Adopted from: EN 4839-003:2018 , 0