IEC 61000-4-36:2020 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 61000-4-36:2020 provides methods to determine test levels for the assessment of the immunity of equipment and systems to intentional electromagnetic interference (IEMI) sources. It introduces the general IEMI problem, IEMI source parameters, derivation of test limits and summarises practical test methods. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - addition of a hyperband and mesoband radiated transients immunity test method in - Annex H; - addition of a calibration method of sensors for radiated hyperband and mesoband transient fields and measurement uncertainty in Annex I.

Document information

  • Redline from IEC
  • Published:
  • Edition: 2
  • Version: 1
  • Document type: IS
  • ICS 33.100.20
  • ISO TC TC 77/SC 77C

Product Relations

Product life cycle